Comanche Peak nuclear power plant 2 is a pressurised water reactor unit at Comanche Peak nuclear power plant in United States rated at 1,250 MW gross. It is operating. Commercial operation began 3 Aug 1993.

Specification
Reactor type Pressurised water reactor (PWR)
ModelWestinghouse 4-loopWH 4LP (DRYAMB) in the source
SizeLargeabove 300 MWe
CoolantLight water
ModeratorLight water
Gross capacity1,250MW
Net capacity (reference)1,195MW
Net capacity (design)1,150MW
Thermal output3,612MWt
NSSS vendorWestinghouse Electric Companyall vendors
Typical enrichment3–5% U-235
Ownership & location
SiteComanche Peak nuclear power plant
Unit2
CountryUnited States
OwnerLuminant Generation Company LLC100%
OperatorLuminant Generation Company
Coordinates 32.2984, -97.7855
Live status NRC daily report, unit key "Comanche Peak 2"
Power level
…
loading
Last 90 days
Updated daily from the US reactor status feed. The NRC publishes a power percentage only, with no reason for a reduction, so a unit at 0% may be refuelling, in a planned outage or tripped. See outages.
Fuel chain for this unit
Fuel form
Uranium dioxide pellets in zirconium-alloy cladding
Enrichment
3–5% U-235
Who makes this assembly
Upstream

Enriched fuel means this unit sits downstream of five conversion plants and four enrichment operators holding 88% of world capacity between the top three.

Fabricator capability is recorded against reactor type and model line, not against named units, utilities do not publish fuel contracts. See the fuel chain.

Timeline

  1. 19 Dec 1974Construction start
  2. 24 Mar 1993First criticality
  3. 9 Apr 1993Grid connection
  4. 3 Aug 1993Commercial operation

Other units at Comanche Peak nuclear power plant

UnitStatusGross MW
Comanche Peak nuclear power plant 1 Operating 1,259
Comanche Peak nuclear power plant 3 Cancelled 1,700
Comanche Peak nuclear power plant 4 Cancelled 1,700

Other WH 4LP (DRYAMB) units

19 units worldwide share this model designation.

UnitCountryStatusGross MW
Alvin W Vogtle nuclear power plant 1 United States Operating 1,229
Alvin W Vogtle nuclear power plant 2 United States Operating 1,229
Braidwood nuclear power plant 1 United States Operating 1,270
Braidwood nuclear power plant 2 United States Operating 1,230
Byron nuclear power plant 1 United States Operating 1,242
Byron nuclear power plant 2 United States Operating 1,210
Callaway nuclear power plant 1 United States Operating 1,275
Comanche Peak nuclear power plant 1 United States Operating 1,259
Diablo Canyon nuclear power plant 1 United States Operating 1,197
Diablo Canyon nuclear power plant 2 United States Operating 1,197
Salem nuclear power plant 1 United States Operating 1,254
Salem nuclear power plant 2 United States Operating 1,200