Turkey Point nuclear power station
Turkey Point nuclear power station is a nuclear power station in United States with 2 operating units totalling 1,658 MW gross. The site has 4 units on record in total.
Units
| Unit | Status | Type | Model | Gross MW | Online |
|---|---|---|---|---|---|
| Unit 3 | PWR | WH 3LP (DRYAMB) | 829 | 1972 | |
| Unit 4 | PWR | WH 3LP (DRYAMB) | 829 | 1973 | |
| Unit 6 | Pre-construction | PWR | AP-1000 | 1,250 | 2036 |
| Unit 7 | Pre-construction | PWR | AP-1000 | 1,250 | 2036 |
Unit by unit
Each unit's rating, type and milestone dates as recorded by the Global Nuclear Power Tracker, with any correction we made to it. A dash or "not disclosed" means the source does not give the value.
Turkey Point nuclear power station 3
GNPT gives a commercial operation date of 1 January 1972, before the unit's own grid connection on 2 November 1972: a year-only placeholder. The World Nuclear Association database lists 14 December 1972.
commercial_operation:
1972-01-01 → 1972-12-14
· World Nuclear Association, Nuclear Reactor Database, Turkey Point 3
· verified 2026-10-22
| Reactor type | Pressurised water reactor (PWR) |
|---|---|
| Model | Westinghouse 3-loop |
| Size class | Large |
| Gross capacity | 829MW |
| Net capacity | 837MW |
| Thermal output | 2,644MWt |
| Enrichment | 3–5% U-235 |
| NSSS vendor | Westinghouse Electric Company |
| Owner | Florida Power & Light Co100% |
| Operator | Florida Power & Light |
| Construction start | 27 Apr 1967 |
|---|---|
| First criticality | 20 Oct 1972 |
| Grid connection | 2 Nov 1972 |
| Commercial operation | 14 Dec 1972 |
Live status, outage record and fuel chain for Turkey Point nuclear power station 3
Turkey Point nuclear power station 4
GNPT gives a commercial operation date of 1 January 1973, before the unit's own grid connection on 21 June 1973: a year-only placeholder. The World Nuclear Association database lists 7 September 1973.
commercial_operation:
1973-01-01 → 1973-09-07
· World Nuclear Association, Nuclear Reactor Database, Turkey Point 4
· verified 2026-10-22
| Reactor type | Pressurised water reactor (PWR) |
|---|---|
| Model | Westinghouse 3-loop |
| Size class | Large |
| Gross capacity | 829MW |
| Net capacity | 821MW |
| Thermal output | 2,644MWt |
| Enrichment | 3–5% U-235 |
| NSSS vendor | Westinghouse Electric Company |
| Owner | Florida Power & Light Co100% |
| Operator | Florida Power & Light |
| Construction start | 27 Apr 1967 |
|---|---|
| First criticality | 11 Jun 1973 |
| Grid connection | 21 Jun 1973 |
| Commercial operation | 7 Sep 1973 |
Live status, outage record and fuel chain for Turkey Point nuclear power station 4
Turkey Point nuclear power station 6 Pre-construction
| Reactor type | Pressurised water reactor (PWR) |
|---|---|
| Model | AP-1000 |
| Size class | Large |
| Gross capacity | 1,250MW |
| Net capacity | not disclosed |
| Thermal output | not disclosed |
| Enrichment | 3–5% U-235 |
| NSSS vendor | Westinghouse Electric Company |
| Owner | Florida Power & Light Co100% |
| Operator | Florida Power & Light |
| Commercial operation | 1 Jan 2036 |
|---|
Turkey Point nuclear power station 7 Pre-construction
| Reactor type | Pressurised water reactor (PWR) |
|---|---|
| Model | AP-1000 |
| Size class | Large |
| Gross capacity | 1,250MW |
| Net capacity | not disclosed |
| Thermal output | not disclosed |
| Enrichment | 3–5% U-235 |
| NSSS vendor | Westinghouse Electric Company |
| Owner | Florida Power & Light Co100% |
| Operator | Florida Power & Light |
| Commercial operation | 1 Jan 2036 |
|---|
Fuel supply
Which fabricators are documented as able to make the fuel this plant's units take. This is capability from our supplier table, not a statement of who the operator buys from: utilities do not publish fuel contracts.
| Fuel | Units here | Documented fabricators | Enrichment |
|---|---|---|---|
| PWR (square-lattice) fuel | 2 | China National Nuclear Corporation, ENUSA Industrias Avanzadas, Framatome, KEPCO Nuclear Fuel, Mitsubishi Heavy Industries, Westinghouse Electric Company | Enriched |
United States runs 63 operating units on PWR (square-lattice) fuel. 6 fabricators are documented for it. Westinghouse Electric Company is based in United States.Country exposure
Turkey Point nuclear power station in context
By gross operating capacity Turkey Point nuclear power station is the 33rd largest of 54 operating nuclear sites in the United States, holding 2% of the country's operating capacity, and ranks 111th of 172 worldwide.
Its operating units started up between 1972 and 1973; the median unit is 53.5 years old, older than the median of 45.0 in the United States.
The 2 units with both construction and grid dates on record took 5.5 to 6.2 years (median 5.8) from construction start to grid connection; the median across all reactors connected in the 1970s is 5.4 years.
The nearest other tracked nuclear sites are St. Lucie nuclear power plant (213 km).
2 operating units are rated differently now from their design net capacities: Unit 3 +20.8% and Unit 4 +18.5%.
Build time by unit
| Unit | Construction start | Grid connection | Years | Fleet median, same decade |
|---|---|---|---|---|
| Unit 3 | 1967 | 1972 | 5.5 | 5.4 (1970s) |
| Unit 4 | 1967 | 1973 | 6.2 | 5.4 (1970s) |
Nearest tracked nuclear sites
| Site | Country | Distance | Operating GW gross |
|---|---|---|---|
| St. Lucie nuclear power plant | United States | 213 km | 2.1 |
How these are worked out: ranks use gross operating capacity; ages count from the start-up year on record, as on the age page; build times run from construction start to grid connection, as on the build-times page; ratings are the tracker's net and design net capacity, as on the uprates page. Distances are straight-line between exact positions, so a site with only an approximate position gets none. A unit missing a date or a rating is left out of the figure that needs it.
Earthquakes nearby
Loading the latest USGS check…
| Time (UTC) | Mag | Depth | Epicentre | Distance |
|---|
Magnitude 4.0 and above within 200 km of Turkey Point nuclear power station's listed coordinates, past 30 days. This is distance, not shaking: it says nothing about damage or any change in operation. Every plant.
| Location | Florida, United States |
|---|---|
| Coordinates | 25.4345, -80.3324 |
| Elevation | about 10 mabove sea level |
| Setting | On the sea coast, 0.4 km from the water |
| Region | Northern America |
| Units by status | Operating: 2 Pre-construction: 2 |
Elevation is read at the listed coordinates from a 30 m terrain model (SRTM 30 m). Two independent models differ by a median of 6 m across our plants and by up to about 40 m on steep or coastal ground, and a point on a shoreline can read as sea level. Distance to the water is measured to a generalised 1:10 million coastline, so a few kilometres or less is not resolved. This is context, not a design-basis or flood-risk figure.
| Owners | Florida Power & Light Co |
|---|---|
| Operators | Florida Power & Light |
Put this plant on your own page: embed a card, or compare it with another plant.
Sources
- Global Nuclear Power Tracker, Global Energy Monitor, August 2026 release , CC BY 4.0 · retrieved 2026-09-06
- GEM.wiki entry (further reading) , CC BY-SA 4.0, linked, not quoted
How these sources are used, including the corrections applied on top of them and what is deliberately left blank · download the underlying data